- Fire Pump System
-
- UL-Listed Fire Pump SetEDJ End Suction Fire Pump SetEDJ Fire Pump SetEJ Small Flow Fire Pump SetFire Pump PackagesContainerized fire pump setDiesel Fire Pump SetED Small fire pump setElectric Jockey Fire Pump SetFire Pump Set with Jockey PumpFire Pump SystemSplit Case Fire Pump SetMutistage EDJ Fire Pump SetDiesel Fire Pump Set with Jockey PumpFire Fighting Pump SystemElectric Diesel Jockey Fire Pump SetFire Fighting Pump Set with Jockey PumpSmall Capacity Electric Fire Pump SetDJ Fire Pump Set with Jockey PumpEJ Fire Pump SetED Fire Pump Set (Electric+Diesel pump)Diesel Engine Fire Pump SetDiesel Fire Jockey PumpSmall Fire Pump SetEDJ Fire Pump SystemFire Water Pump SetFire Pump AssemblyDJ Small Flow Fire Pump SetCummins Engine Fire Pump Set
- Mobile Pump Unit
-
- Split Case Series Mobile Pump TruckSelf Priming Series Mobile Pump TruckCentrifugal diesel driven dewatering pumps open frame trailerFlow-mixing Mobile Pump TruckFlow-mixing Mobile Pump TruckManure Pump TruckP12 modle mobile Pump truckP10 Modle Mobile Pump Truck1000m³Self Priming Series Mobile Pump TruckLarge Flow Non-Clogging Mobile Fire Pump TrailerTrailer Mounted Fire PumpFire Emergency Mobile Pump TruckDiesel Engine Emergency Mobile Trailer Pump
- Diesel Fire Pump
-
- UL Listed Diesel End Suction Fire PumpXBC-S Diesel Split Case Fire PumpXBC-IS Diesel End Suction Fire PumpXBC-D Diesel Multistage Fire PumpVertical Turbine Diesel Engine Fire PumpDiesel Engine Single-Stage Centrifugal PumpXBC-IS Diesel End Suction Fire Fighting PumpXBC-S Diesel Engine Split Case Fire PumpDiesel Engine End Suction Fire PumpXBC-IS Diesel End Suction Fire PumpsZWC Diesel Engine Self Priming Pump for IrrigationDiesel Engine End Suction Fire Fighting PumpXBC-S Heat Exchange Diesel End Suction Fire PumpXBC-XA Diesel Engine End Suction Fire PumpXBC-IS Diesel Engine Fire PumpDiesel Engine End Suction Fire PumpXBC-IS Diesel Engine End Suction Fire PumpXBC-ISO Diesel Fire Fighting PumpPortable Fire PumpFire Booster Pump
Email: zjbetter@119pump.com
Tel:+86 15336708022(Gloria) +86 13306708055 (Ivy) +86 13357006058 (Serena) +86 13357022877 (Wendy) +86 17757009882(Kate)
Fax:0086-570-3010238
-
- Multi-stage fire pump failure
- 2023.04.24
- Vertical multi-stage fire pump is a type of fire protection system designed to provide adequate pressure and flow for fire suppression in high rise buildings. The system typically consists of two or more stages of pumps, each with a different set of impellers, that are arranged in a vertical configuration. This type of system is typically used in buildings with a large number of floors that require a high level of pressure and flow for fire suppression. The pumps can be either electric or diesel powered, depending on the requirements of the building and the local fire code.
-
- Features and maintenance of single-stage fire pump
- 2023.04.24
- The single-stage fire pump consists of two parts, the motor and the pump. The fire pump and the motor are coaxial. The pump structure includes the pump body, impeller, pump cover, and mechanical seal. The inlet and outlet of the pump are on the same horizontal axis, and the caliber and specification are the same, which is very convenient for loading and unloading, and occupies a small area. The pump is equipped with a mounting base, which is easy to install and increases the stability of the pump operation. The pump seal of XB fire pump produced by Shanghai Zibo Zhengji Pump Industry adopts m
-
- The reason why the fire pump does not supply water
- 2023.04.24
- The fire pump has become the most widely used fire pump because of its simple structure, convenient use and maintenance, and high efficiency. However, it is also troublesome because sometimes the centrifugal fire pump cannot lift water. The reason for the failure of the fire pump to lift the water.
-
- What to do if the fire pump is corroded?
- 2023.04.20
- The fire pump has brought great convenience to our life. Environmental protection and fire departments cannot do without it. It is synonymous with creating no l...
-
- Diesel engine fire water pump failure in use
- 2023.04.20
- The vibration of the diesel engine water pump can be felt. Touch the motor end and the pump head end separately with your hands. If only the motor vibrates, there may be a problem with the coupling or the motor bearing. If only the pump head vibrates strongly, it may be caused by the pump head bearing, mechanical seal, or impeller nut, or cavitation.
-
- Why fire pump set should be equipped with a control cabinet?
- 2023.04.18
- Fire pump set should be equipped with a control cabinet to ensure that the pump is operated in a safe manner. The control cabinet houses all of the essential components necessary to monitor and control the operation of the fire pump, including the pump motor, pressure switches, pressure gauges, and other safety devices. The control cabinet also provides an easy way to access the components when needed for maintenance.
-
- Why diesel engine fire pump does not discharge water?
- 2023.04.18
- During the use of the fire pump, there may be some abnormal failures. Once you find an abnormality or failure, you need to stop and carefully check and analyze it to resolve the failure, then you can use it safely.
-
- Single stage fire pump features
- 2023.04.17
- The single-stage fire pump consists of two parts, the motor and the pump. The fire pump and the motor are coaxial. The pump structure includes the pump body, impeller, pump cover, and mechanical seal. The inlet and outlet of the pump are on the same horizontal axis, and the caliber and specification are the same, which is very convenient for loading and unloading, and occupies a small area. The pump is equipped with a mounting base, which is easy to install and increases the stability of the pump operation. The pump seal of XB fire pump produced by Shanghai Zibo Zhengji Pump Industry adopts m
-
- Troubleshooting and commissioning of fire pumps
- 2023.04.17
- After a certain period of use, the fire pump should be disassembled and repaired (the period of medium repair is 6 months, and the period of overhaul is 12 mont...
-
- Fire pump install
- 2023.04.13
- The fire pump should be installed in accordance with the manufacturer’s instructions and local building codes. The pump should be installed on a level surface, and the suction and discharge pipes should be properly sized. It is important to provide proper backflow protection and to ensure that the pump is adequately supplied with the necessary power source. The pump should be tested for proper operation before it is put into service.
-
- The difference between single-stage fire pumps and multi-stage fire pumps
- 2023.04.13
- Single-stage fire pumps are designed to pump water at a constant pressure, while multi-stage fire pumps provide a higher pressure at the outlet by using a series of impellers and diffusers. Single-stage pumps are simpler, require less maintenance, and are more cost-effective than multi-stage pumps. Multi-stage pumps are more efficient and can provide a higher pressure, making them ideal for higher-pressure applications such as sprinkler systems.
-
- XBC-IS diesel fire pump operating conditions
- 2023.04.11
- XBC-IS diesel fire pump has the feature of compact structure, easy maintenance, simple operation, high degree of automation of a product among the current diese...
-
- Talk about fire pump room function
- 2023.04.11
- In order to ensure that the fire pump does not ask the water supply, a group of fire pumps suction pipe should not be less than two. When one of them is damaged, the rest of the suction pipe passes through the full amount of water.
-
- What are the characteristics and usage methods of horizontal and vertical fire pumps
- 2023.04.10
- From the perspective of occupied space, the occupied space of vertical fire pump is smaller than that of horizontal fire pump. Generally, vertical fire pump does not need to lay foundation, while horizontal fire pump set has a base and needs to lay foundation. From the perspective of maintenance, the upper part of the vertical fire pump needs to be removed to repair the impeller, which is difficult to repair; the horizontal fire pump is relatively simple, as long as the inlet pipe is removed, the impeller can be repaired.
-
- Fire engine heat dissipation for fire pump
- 2023.03.30
- The diesel engine fire pump has the characteristics of good start, strong overload capability, compact and reasonable structure, convenient maintenance, simple and reliable use, etc. It is often used in large-scale project engineering emergency water supply projects such as high-rise buildings, water companies, steel plants, wineries, chemical plants, hotels, hospitals, etc. The diesel engine fire pump has perfect indication system: ready to start, manual start, automatic start, unit operation, unit shutdown, battery charging, overspeed, low diesel engine oil pressure, low supercharger oil pr
-
- Commonly used material properties for fire pumps
- 2023.03.30
- Better Technology Group Co.,Ltd is an enterprise specializing in the design, development, manufacture of water pumps and related complete sets of equipment, wit...
-
- Why is the diesel engine fire pump very hot after starting for a while?
- 2023.03.30
- As people's awareness of fire protection continues to increase, enterprises, units, and individuals pay more and more attention to fire protection systems, and diesel engine fire pumps are also favored by more and more people. With the development of the fire fighting equipment industry, the various automation performances of diesel engine fire pumps are becoming more and more perfect. The diesel engine fire pumps developed so far have various automation, intelligence, remote control, automatic alarm and other functions.
-
- How to install XBD electric fire pump?
- 2023.03.28
- The first step is to check the condition of the water pump. Guarantee that the XBD fire pump is intact, the structure is complete, the seal is good, and the tes...
-
- Which pump is suitable for fire fighting?
- 2023.03.28
- Fire pumps are designed to provide the necessary water pressure and flow rate for fighting fires. Centrifugal pumps are the most common type of pump used for fi...
-
- What is the flow, lift and power of fire pump?
- 2023.03.24
- Head, flow and power of fire pump 1. Flow: The flow of the pump is also called the water delivery volume, which refers to the amount of water delivered by...
-
- How do you maintain your fire pump?
- 2023.03.24
- A fire pump is a device used to provide a high-pressure flow of water to a fire sprinkler system. It is typically powered by an electric motor or diesel engine ...
-
- Maintenance of diesel engine fire pump
- 2023.03.23
- Diesel engine fire pumps are deeply loved by users because of their large flow and wide head, and they have occupied a certain market. With the increasing use o...
-
- How to select deep well vertical fire pump?
- 2023.03.23
- Proper selection of deep well vertical fire pump can prolong the service life of pumps, motors, and water wells, so how to choose a suitable deep well vertical ...
-
- What is the difference between multi-stage pumps and single-stage pumps?
- 2023.03.22
- A multi-stage pump is a type of pump that uses multiple impellers to increase the pressure of the water it pumps. It can produce higher pressures than a single...