- Fire Pump System
-
- UL-Listed Fire Pump SetEDJ End Suction Fire Pump SetEDJ Fire Pump SetEJ Small Flow Fire Pump SetFire Pump PackagesContainerized fire pump setDiesel Fire Pump SetED Small fire pump setElectric Jockey Fire Pump SetFire Pump Set with Jockey PumpFire Pump SystemSplit Case Fire Pump SetMutistage EDJ Fire Pump SetDiesel Fire Pump Set with Jockey PumpFire Fighting Pump SystemElectric Diesel Jockey Fire Pump SetFire Fighting Pump Set with Jockey PumpSmall Capacity Electric Fire Pump SetDJ Fire Pump Set with Jockey PumpEJ Fire Pump SetED Fire Pump Set (Electric+Diesel pump)Diesel Engine Fire Pump SetDiesel Fire Jockey PumpSmall Fire Pump SetEDJ Fire Pump SystemFire Water Pump SetFire Pump AssemblyDJ Small Flow Fire Pump SetCummins Engine Fire Pump Set
- Mobile Pump Unit
-
- Split Case Series Mobile Pump TruckSelf Priming Series Mobile Pump TruckCentrifugal diesel driven dewatering pumps open frame trailerFlow-mixing Mobile Pump TruckFlow-mixing Mobile Pump TruckManure Pump TruckP12 modle mobile Pump truckP10 Modle Mobile Pump Truck1000m³Self Priming Series Mobile Pump TruckLarge Flow Non-Clogging Mobile Fire Pump TrailerTrailer Mounted Fire PumpFire Emergency Mobile Pump TruckDiesel Engine Emergency Mobile Trailer Pump
- Diesel Fire Pump
-
- UL Listed Diesel End Suction Fire PumpXBC-S Diesel Split Case Fire PumpXBC-IS Diesel End Suction Fire PumpXBC-D Diesel Multistage Fire PumpVertical Turbine Diesel Engine Fire PumpDiesel Engine Single-Stage Centrifugal PumpXBC-IS Diesel End Suction Fire Fighting PumpXBC-S Diesel Engine Split Case Fire PumpDiesel Engine End Suction Fire PumpXBC-IS Diesel End Suction Fire PumpsZWC Diesel Engine Self Priming Pump for IrrigationDiesel Engine End Suction Fire Fighting PumpXBC-S Heat Exchange Diesel End Suction Fire PumpXBC-XA Diesel Engine End Suction Fire PumpXBC-IS Diesel Engine Fire PumpDiesel Engine End Suction Fire PumpXBC-IS Diesel Engine End Suction Fire PumpXBC-ISO Diesel Fire Fighting PumpPortable Fire PumpFire Booster Pump
Email: zjbetter@119pump.com
Tel:+86 15336708022(Gloria) +86 13306708055 (Ivy) +86 13357006058 (Serena) +86 13357022877 (Wendy) +86 17757009882(Kate)
Fax:0086-570-3010238
-
- The role of the fire controller - fire pump partner
- 2019.05.15
- fire controller have been installed under the full fire protection system. In the early years, fire controller were unnecessary for many people, but this is not the case. The fire controller is also an indispensable...
-
- The sealing of fire pumps is one key factor in measuring the quality of fire pumps, it can not be ignored!
- 2019.04.30
- The surface of the auxiliary seal ring is smooth and flat, and there must be no bubbles, cracks, gaps, etc.; the size of the end face should be uniform; the burr...
-
- Design considerations of integrated prefabricated pump station
- 2019.04.03
- The integrated prefabricated pumping station is a new type of environmental protection new-generation pumping station that upgrades sewage, rainwater, drinking water, waste water, etc...
-
- The advantages of integrated lift pump station
- 2019.03.20
- The integrated lift pump station generally uses gravity flow to pass through various structures and equipment in the operating process. The lifting pump station must be added to...
-
- Deep Well Submersible pump - Better Technology CO., LTD.
- 2019.03.06
- The deep well submersible pump is a pump that is immersed in a groundwater well for pumping and transporting water. It is widely used in farmland irrigation and drainage, industrial and mining enterprises...
-
- The Common Troubleshooting Methods of Sewage pump
- 2019.02.27
- The self priming sewage pump integrates self priming and non-blocking sewage discharge, adopts axial recirculation and external mixing, and through the unique design of the pump body and impeller flow passage...
-
- Reasons for pressure drop in multistage centrifugal pumps
- 2019.02.20
- The multistage centrifugal pump is a combination of two or more centrifugal pumps having the same function. On the fluid passage structure, the medium pressure discharge port shown in the first stage communicates...
-
- The gear oil pump working principle and application
- 2019.02.13
- The gear oil pump is a horizontal slewing gear pump. It is divided into two types: motor-driven and diesel-driven. It is suitable for conveying various oils and other lubricated medium liquids...
-
- What are the characteristics of the GDL vertical multistage centrifugal pump?
- 2019.01.30
- GDL vertical multistage centrifugal pump features: 1. Advanced hydraulic model: high efficiency and wide performance range. 2. installation, maintenance is convenient: pipeline installation, import and...
-
- Centrifugal pump air binding - Better Technology CO., LTD.
- 2019.01.23
- The air binding is mainly due to the fact that the centrifugal pump is not filled with liquid before starting, the air is present in the pump casing, the air density is small, and the centrifugal force generated is also small...
-
- How do you stop a fire pump from cavitating? - Better Technology CO., LTD.
- 2019.01.16
- In the use of machinery and equipment for many years, there will be more or less such a problem, which is normal in the eyes of ordinary people, but from a professional point of view, this is not the case...
-
- How often does a diesel engine fire pump need to be tested?
- 2019.01.07
- In order to improve the ability of the diesel fire pump to respond to fire signals, it is recommended to inspect it once a week. Taking into account the water hammer effect and the characteristics of the diesel engine itself...
-
- Application notice of diesel engine self-priming pump - Better Technology CO., LTD.
- 2019.01.04
- Use of diesel engine self-priming pump: (1) Preparation and inspection before starting: 1. This series of diesel engine self-priming pumps are lubricated with high-quality calcium-based butter and No. 10 oil...
-
- 7 Automatic Protection Functions of the Diesel Engine Fire Pump
- 2018.12.25
- The automatic protection functions of the diesel engine fire pump are: (1) Start protection: If the diesel engine fire pump unit fails to start three times, the start failure signal is output and the automatic working system is blocked. Buzzer alarm.
-
- How to Correctly reduce power consumption rate of Diesel engine fire pump?
- 2018.12.19
- With the changes of the times, people's awareness of safety has increased. For the protection of their own security, it is already more and more costly. Today, diesel fire pumps are slowly...
-
- The Basic Parameters that Characterize the Pump Performance
- 2018.12.17
- The basic parameters that characterize the main performance of the pump are as follows: 1, flow Q. Flow is the amount (volume or mass) of liquid that the pump delivers per unit of time. The volume flow rate is expressed by Q, and the unit is: m3/s, m3/h, l/s, and the like...
-
- The pump application in various fields - Better Technology CO., LTD.
- 2018.12.14
- From the pump performance range, the flow rate of the giant pump can reach several hundred thousand cubic meters per hour, while the flow rate of the micro pump is below several tens of milliliters per hour...
-
- The classification of the pumps - Better Technology CO., LTD.
- 2018.12.13
- There are many kinds of pumps, which can be divided into: ①power pump, also called impeller pump or vane pump, relying on the dynamic force of the rotating impeller to transfer...
-
- What is a pump and historical source? - Better Technology CO., LTD.
- 2018.12.12
- Pumps can usually be divided into three types according to the working principle: positive displacement pumps, power pumps and other types of pumps...
-
- Pump Room Management System of Diesel Engine fire pump
- 2018.12.11
- The diesel engine fire pump is a key part of providing fire water. It is an important part directly related to property safety. To manage the pump house and clarify its responsibilities, the following system is formulated...
-
- The Composition of Single stage single suction pump and Single stage multi-suction pump
- 2018.12.06
- The XBD-W single-suction single-stage fire pump consists of two parts: the motor and the pump. The fire pump and the motor are coaxial. The pump structure consists of the pump body, the impeller...
-
- Why does stainless steel rust? - Better Technology CO., LTD.
- 2018.12.04
- Stainless steel has the ability to resist atmospheric oxidation - that is, rust, and also has the ability to corrode in acids, alkalis, and salts - that is, corrosion resistance. However, the magnitude...
-
- How to improve the running life of vertical pipe pump?
- 2018.11.29
- Vertical pipeline pumps are widely used in high and low-temperature oil transportation in petroleum, chemical, metallurgy, mining, power stations and other fields, as well as in oil supply systems...
-
- Analysis of engineering application of the submersible sewage pump
- 2018.11.28
- The submersible sewage pump is a kind of pump which is connected with the pump and the motor and submerged under the liquid. Compared with the general horizontal pump...